Look-up in Google Scholar
Full metadata record
Yaya Beas, Rosa Elena
Echevarria Chávez, Javier Santiago
Echevarria Chávez, Javier Santiago
2022-01-23T01:31:24Z
2022-01-23T01:31:24Z
2020
http://hdl.handle.net/20.500.14076/21647
La investigación fue realizada en el CITRAR FIA – UNI, donde se construyó un reactor UASB modificado a escala real, con un caudal de diseño de 13.82 m3/día que en el ámbito rural equivaldría aproximadamente a 231 habitantes beneficiados (considerando una dotación de 60 L/hab/día), el reactor tuvo dimensiones totales de 1.70 m de diámetro interno y altura total de 2.10 m (altura útil = 1.60 m) con un TRH y velocidad de ascenso de 6.3 horas y 0.25 m/h, respectivamente. De acuerdo a los resultados obtenidos, este tipo de reactores opera eficientemente como un sedimentador avanzado, las eficiencias de remoción para la turbiedad, DQO total, DQO particulada, DQO coloidal y DQO soluble fueron, 78%, 50%, 63%, 52% y 21%, respectivamente. Si se observan los resultados de la DQO particulada y la DQO soluble, se aprecia que el operó en mayor medida como un retenedor de material particulado, esto es, que la actividad biológica no fue la esperada en comparación con su tecnología avanzada (reactores UASB) El periodo de arranque del reactor se estableció en 149 días bajo las condiciones de operación que se tuvieron durante el tiempo que duró la investigación, es a partir de este periodo en el que el reactor comenzó a mostrar mejor estabilidad en sus eficiencias de remoción de las DQO mencionadas, salvo la DQO soluble. Se realizó la inoculación de lodo anaerobio proveniente del reactor UASB del CITRAR FIA – UNI, y durante la investigación no se observó un crecimiento significativo de lodo en el interior del reactor UASB modificado. Al realizar las mediciones de metano producido, no se encontró una relación directa entre los volúmenes de metano y la DQO soluble. (es)
The research was carried out in the CITRAR FIA - UNI, where a modified UASB reactor was built on a real scale, with a design flow of 13.82 m3/day that in the rural area would be equivalent to approximately 231 habitants benefited (considering a provision of 60 L/inhab/day), the reactor dimensions were 1.70 m internal diameter and total height of 2.10 m (useful height = 1.60 m) with a HRT and upflow velocity of 6.3 hours and 0.25 m / h, respectively. According to the obtained results, the UASB septic tank operates efficiently as an improved settler, the removal efficiencies for turbidity, total COD, particulate COD, colloidal COD and soluble COD were, 78%, 50%, 63%, 52% and 21%, respectively. If the results of the particulate COD and the soluble COD are observed in the effluent, it can be seen that it operated as a settler of particulate material, that is, that the biological activity was not as expected compared to its advanced technology (UASB reactors) The start-up period was set at 149 days under the operating conditions during the time the research lasted, then the reactor showed better stability in its removal efficiencies of the turbidity, total COD, particulate COD and colloidal COD, but it is not soluble COD. The anaerobic sludge from the UASB reactor of the CITRAR FIA-UNI was used as an inoculation source. During the research no significant growth of sludge was observed inside the modified UASB reactor. When measuring the produced methane, no direct relationship was found between the methane volumes and soluble COD. (en)
Tesis (es)
application/pdf (es)
spa (es)
Universidad Nacional de Ingeniería (es)
info:eu-repo/semantics/openAccess (es)
http://creativecommons.org/licenses/by-nc-nd/4.0/ (es)
Universidad Nacional de Ingeniería (es)
Repositorio Institucional - UNI (es)
Reactor UASB (es)
Actividad biológica (es)
Eficiencias de remoción de las DQO (es)
Lodo anaerobio (es)
Evaluación de la actividad biológica en términos de la remoción de la DQO soluble en un reactor UASB modificado (es)
info:eu-repo/semantics/bachelorThesis (es)
Universidad Nacional de Ingeniería. Facultad de Ingeniería Ambiental (es)
Ingeniería Sanitaria (es)
Título Profesional (es)
Ingeniero Sanitario (es)
PE (es)
http://purl.org/pe-repo/ocde/ford#2.11.02 (es)
Ingeniería (es)
http://purl.org/pe-repo/renati/nivel#tituloProfesional (es)
10040514
https://orcid.org/0000-0002-6140-4266 (es)
43724286
733016
Salazar Gavelán, Roger Edmundo
Rosasco Gerkes, Otto Bruno
http://purl.org/pe-repo/renati/type#tesis (es)
Pública



This item is licensed under a Creative Commons License Creative Commons