Look-up in Google Scholar
Title: ?Variaci?n del eje el?ctrico medio en funci?n al posicionamiento del paciente durante el registro electrocardiogr?fico.?
Advisor(s): Bezold Arnillas, Ursula
OCDE field: https://purl.org/pe-repo/ocde/ford#4.03.01
Issue Date: 2016
Institution: Universidad Ricardo Palma - URP
Abstract: La electrocardiograf?a es una herramienta b?sica diagn?stica en la medicina veterinaria de animales de compa??a, siendo la mejor alternativa para evaluar la actividad el?ctrica del coraz?n en forma no invasiva. Sin embargo, cambios en el posicionamiento del paciente pueden ocasionar cambios en las medidas del complejo PQRST y desencadenar diagn?sticos errados. El prop?sito de este estudio fue detectar posibles variaciones de la direcci?n del eje el?ctrico medio cuando el registro se hace en posici?n dec?bito lateral izquierdo en lugar de la posici?n est?ndar en dec?bito lateral derecho, para analizar la variaci?n en los resultados de acuerdo al posicionamiento del paciente. El estudio se realiz? en 100 canes aparentemente sanos de ambos sexos, mayores a 1 a?o de edad y de cualquier peso. Se registraron dos electrocardiogramas por cada paciente: dec?bito lateral derecho e izquierdo, que luego fueron analizados uno por uno; los resultados del c?lculo del eje el?ctrico medio fueron comparados, llegando a la conclusi?n que no son similares y que la posici?n dec?bito lateral derecho es irreemplazable para el c?lculo del eje el?ctrico medio cardiaco en caninos.Electrocardiography is a basic diagnostic tool in veterinary medicine pet, being the best non-invasively alternative to assess the electrical activity of the heart. However, changes in patient positioning may cause changes in measures of PQRST complex and trigger misdiagnoses. The purpose of this study was to detect possible changes in the direction of the mean electrical axis when the register is in left lateral position (LL) instead of the standard right lateral position (RL), to analyze the variation in results according to patient positioning. The study was conducted in 100 apparently healthy male and female dogs, older than 1 year of age and of any weight. Two electrocardiograms were registered for each patient: right and left lateral decubitus, which were then analyzed one by one; two electrocardiograms were performed for each patient the results of the calculation of the average electrical axis were compared, concluding that they are not similar and that the right lateral decubitus position is irreplaceable for calculating mean electrical axis of the heart in dogs.
Discipline: Medicina Veterinaria
Grade or title grantor: Universidad Ricardo Palma. Facultad de Ciencias Biol?gicas. Escuela Profesional de Ciencias Veterinarias
Grade or title: M?dica Veterinaria
Register date: 31-May-2017



This item is licensed under a Creative Commons License Creative Commons