Abstract: Perú está ubicado en uno de los continentes que presentan mayor actividad sísmica causando muchas pérdidas humanas y daños excesivos en elementos estructurales y no estructurales, así mismo para disminuir estos movimientos sísmicos se ha estudiado un sistema de protección sísmica llamado Amortiguamiento de masa sintonizada con el fin de aumentar el desempeño sísmico, El edificio analizado es: las dos torres de Salaverry ubicado en la ciudad de Chiclayo del territorio Peruano, Dicho amortiguamiento de masa sintonizada se ha colocado en la parte final del edifico con el propósito de disminuir los desplazamientos laterales ,Los Análisis utilizados han sido el Estatico,Dinamico Y el Análisis tiempo historia cumpliendo también con los requisitos de la Norma E030 , Para el análisis tiempo historia se han seleccionado los sismos ocurridos en Piura el 18 de octubre de 2021 y el 3 de febrero Condorcanqui Amazonas y uno de los sismos más fuertes de Perú que es de lima 1974, de los resultados obtenidos se ha concluido que este sistema de amortiguamiento de masas sintonizada al incorporar a edificios reduce considerablemente los desplazamientos laterales, resultando ser uno de sistemas de protección sísmica favorable

Peru is located in one of the continents that present the greatest seismic activity, causing many human losses and excessive damage to structural and non-structural elements. Likewise, in order to reduce these seismic movements, a seismic protection system called Tuned mass damping has been studied in order to increase the seismic performance, The analyzed building is the two Salaverry towers located in the city of Chiclayo in the Peruvian territory, This tuned mass damping has been placed in the final part of the building with the purpose of reducing lateral displacements, The Analyzes used have been the Static, Dynamic and Time History Analysis, also complying with the requirements of Standard E030. For the time history analysis, the earthquakes that occurred in Piura on October 18, 2021 and February 3, Condorcanqui Amazonas and one of the strongest earthquakes in Peru, which is from Lima 1974, of the results obtained It has been concluded that this tuned mass damping system when incorporated into buildings considerably reduces lateral displacements, turning out to be one of the favorable seismic protection systems.
Discipline: Ingeniería Civil Ambiental
Grade or title grantor: Universidad Católica Santo Toribio de Mogrovejo. Facultad de Ingeniería
Grade or title: Ingeniero Civil Ambiental
Juror: Céspedez Deza, José Alfredo Rolando; Acero Martínez, José Alberto; Alvarez Ruffran, Jorge Enrique
Register date: 5-Jun-2024



This item is licensed under a Creative Commons License Creative Commons