Buscar en Google Scholar
Registro completo de metadatos
Torres Navarro, John Paul (es_PE)
Flores Mejia, Jose Orlando
Chiclayo (es_PE)
Flores Mejia, Jose Orlando
2024-05-09T20:46:15Z
2024-05-09T20:46:15Z
2024
Flores J. Resistencia a la fractura de dientes con reabsorción radicular interna reparadas con diferentes selladores de conductos radiculares: estudio in vitro [Tesis de segunda especialidad]. Chiclayo: Universidad Católica Santo Toribio de Mogrovejo; 2024. 82 p. Disponible en: (es_PE)
RTU006905
http://hdl.handle.net/20.500.12423/7221
El objetivo del presente estudio fue determinar in vitro que grupo de dientes analizados con reabsorción radicular interna tratados endodónticamente y reparados con tres distintos selladores presentó la mayor resistencia a la fractura. Metodología, el estudio fue de nivel básica; de tipo prospectivo, longitudinal y exploratorio; de diseño experimental in vitro; y de enfoque cuantitativo. La población, estuvo conformada por piezas dentarias del grupo premolar mandibulares y de un sólo conducto radicular; la muestra, fue conformada de manera no aleatoria por conveniencia, constituida por 60 piezas dentarias, divididas en seis grupos de 10 dientes cada uno (A: Biodentine + Biodentine, B: Biodentine + gutapercha + Neo Sealer, C: Neo Putty + Neo Putty, D: Neo Putty + gutapercha + cemento Neo sealer, grupo control positivo y grupo control negativo); asimismo, se consideró los criterios de inclusión y exclusión. Para la medición de la resistencia a la fractura se utilizó la máquina universal Instron, en el Laboratorio High Technology Laboratory Certificate S.A.C, San Juan de Lurigancho – Lima, 2023. Resultados, se halló que la resistencia a la fractura promedio de los grupos control positivo y negativo fueron 558.147N y 648.212N, respectivamente; y, la resistencia a la fractura promedio en los grupos experimentales fueron los siguientes: 485.938N para el grupo D, 419.382N para el grupo A, 410.417N para el grupo C y 407.824N para el grupo B. Además, se mostró que existe diferencia significativa entre las medias resistencia a la fractura de los dientes de los grupos experimentales con respecto a los grupos controles, pues los grupos controles tuvieron un mayor rango promedio de la resistencia a la fractura que los dientes tratados con los sellantes endodónticos (p-valor = 0.002, p<0.05). Conclusión, se concluyó que entre los grupos experimentales, el grupo sellador Neo Putty + gutapercha + sellador Neo Sealer fue aquel que mostró la mayor resistencia a la fractura en los dientes con reabsorción radicular interna tratados endodónticamente; sin embargo, esta resistencia fue menor a la hallada en los grupos controles. (es_PE)
The purpose of the present study was to determine in vitro which group of teeth analyzed with internal root resorption treated endodontically and repaired with three different sealants presented the greatest resistance to fracture. Methodology, the study was basic level; prospective, longitudinal and exploratory; in vitro experimental design; and quantitative approach. The population was made up of teeth from the mandibular premolar group and a single root canal; The sample was formed in a non-random manner for convenience, consisting of 60 teeth, divided into six groups of 10 teeth each (A: Biodentine + Biodentine, B: Biodentine + gutta-percha + Neo Sealer, C: Neo Putty + Neo Putty, D: Neo Putty + gutta percha + Neo sealer cement, positive control group and negative control group); Likewise, the inclusion and exclusion criteria were considered. To measure the fracture resistance, the Instron universal machine was used, at the High Technology Laboratory Certificate S.A.C, San Juan de Lurigancho – Lima, 2023. Results, it was found that the average fracture resistance of the positive control groups and negative were 558.147N and 648.212N, respectively; and, the average fracture resistance in the experimental groups were as follows: 485.938N for group D, 419.382N for group A, 410.417N for group C and 407.824N for group B. In addition, it was shown that there is significant difference between the average fracture resistance of the teeth of the experimental groups with respect to the control groups, since the control groups had a greater average range of fracture resistance than the teeth treated with endodontic sealants (pvalue = 0.002, p<0.05). Conclusion, it was concluded that among the experimental groups, the Neo Putty sealer + gutta-percha + Neo Sealer sealer group was the one that showed the greatest resistance to fracture in teeth with endodontically treated internal root resorption; However, this resistance was lower than that found in the control groups. (es_PE)
application/pdf (es_PE)
spa (es_PE)
Universidad Católica Santo Toribio de Mogrovejo (es_PE)
info:eu-repo/semantics/embargoedAccess (es_PE)
http://creativecommons.org/licenses/by/4.0/ (es_PE)
Resistencia a la fractura (es_PE)
Reabsorción radicular interna (es_PE)
Selladores endodónticos (es_PE)
Fracture resistance (es_PE)
Internal root resorption (es_PE)
Endodontic sealants (es_PE)
Resistencia a la fractura de dientes con reabsorción radicular interna reparadas con diferentes selladores de conductos radiculares: estudio in vitro (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Católica Santo Toribio de Mogrovejo. Facultad de Medicina (es_PE)
Odontología Carielogía y Endodoncia (es_PE)
Segunda Especialidad en Odontología Carielogía y Endodoncia (es_PE)
PE (es_PE)
http://purl.org/pe-repo/ocde/ford#3.03.01 (es_PE)
http://purl.org/pe-repo/renati/nivel#tituloSegundaEspecialidad (es_PE)
09857723
https://orcid.org/0000-0002-9664-4454 (es_PE)
27754095
911079 (es_PE)
Torres Verastegui, Rocío Lizet (es_PE)
Díaz Silva, Carmen Lizeth (es_PE)
Torres Navarro, John Paul (es_PE)
http://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada asociativa



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons