Title: Comparación del desempeño sísmico del puente Quilca sin sistemas de protección sísmica y aplicando sistemas de aislamiento y disipación de energía
Advisor(s): Asmat Garaycochea, Christian Alberto
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 19-Aug-2022
Institution: Pontificia Universidad Católica del Perú
Abstract: El objetivo principal de la presente tesis es aportar al estado del arte del diseño sismo resistente de puentes con sistemas de protección sísmica, mediante la comparación del desempeño sísmico de un puente con aisladores y un puente con aisladores sísmicos más disipadores de fluido viscoso, para lo cual se tomó el caso de estudio del puente Quilca. Se determinó el desempeño sísmico del puente Quilca frente a la demanda sísmica del Manual de Puentes del MTC 2017, mediante un análisis estático no lineal (push over), tanto en la dirección longitudinal como en la dirección transversal. Luego se establecieron 3 casos de estudio; el primero considera al puente Quilca en su estado existente, el segundo caso considera la inclusión de un sistema de aislamiento sísmico con dispositivos con núcleo de plomo LRB, y el tercer caso considera la inclusión de un sistema de protección híbrido, conformado por un sistema de aislamiento sísmico con inclusión de disipadores de fluido viscoso. Se realizaron análisis sísmicos modales espectrales y tiempo historia no lineal, para los 3 casos de análisis mencionados, obteniéndose registros de desplazamientos, fuerzas cortantes y momentos flectores, periodos fundamentales, amortiguamiento, entre otros. En el capítulo de análisis de resultados, se resumen los resultados obtenidos en cada caso de estudio, y se discuten los mismos. Finalmente se comparan los 3 caso de estudio, analizando cara parámetro mediante gráficas comparativas, y determinando la alternativa con mejor desempeño sísmico.

The main thesis objective is to contribute to the state of the art of earthquake resistant design of bridges with seismic protection systems, by comparing the seismic performance of a bridge with seismic isolators and a bridge with seismic isolators plus viscous fluid dampers, for which which took the case study of the Quilca bridge. The seismic performance of the Quilca bridge was determined against the seismic demand of the MTC 2017 Bridge Manual, by means of a nonlinear static analysis (push over), both in the longitudinal direction and in the transverse direction. Then 3 case studies were established; the first considers the Quilca bridge in its existing state, the second almost considers the inclusion of a seismic isolation system with devices with LRB lead core, and the third case considers the inclusion of a hybrid protection system, made up of a system of seismic isolation and the inclusion of viscous fluid dampers. Modal spectral seismic analyzes and non-linear time history were realized for the 3 cases of analysis mentioned, obtaining records of displacements, shear forces and bending moments, fundamental periods, damping, among others. In the analysis of results chapter, the results obtained in each case study are summarized and discussed. Finally, the 3 case studies are compared, analyzing each parameter through comparative graphs, and determining the alternative with the best seismic performance.
Discipline: Ingeniería Civil con mención en Estructuras Sismorresistentes
Grade or title grantor: Pontificia Universidad Católica del Perú. Escuela de Posgrado
Grade or title: Maestro en Ingeniería Civil con mención en Estructuras Sismorresistentes
Juror: Casabonne Rasselet, Carlos; Asmat Garaycochea, Christian Alberto; Santos Cavalho, Dennis Jesus