Look-up in Google Scholar
Title: Comportamiento no lineal de los sistemas estructurales Emmedue y muro de ductilidad limitada aplicada al Hotel Costa Blanca - Vichayito - Piura 2022
Advisor(s): Tello Malpartida, Omar Demetrio
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 13-Aug-2022
Institution: Universidad Privada del Norte
Abstract: El trabajo de investigación tuvo como objetivo determinar la influencia de los sistemas estructurales Emmedue y Muros de Ductilidad Limitada en el comportamiento no lineal del hotel Costa Blanca ubicado en Vichayito, Piura; el tipo de investigación fue aplicada, cuantitativa, de nivel explicativa, con un diseño cuasi experimental; la población estuvo conformada por las edificaciones para hoteles cuyo sistema estructural este basado en Emmedue o Muros de Ductilidad Limitada en Vichayito, Piura; mientras que la muestra estuvo constituida por el hotel Costa Blanca la cual será analizada bajo los sistemas Emmedue y Muros de Ductilidad Limitada. Con la ayuda del programa Etabs V19, se modelizó la edificación para ambos sistemas con la finalidad de poder conocer el comportamiento no lineal estático de la estructura, obteniendo los siguientes resultados: El sistema Emmedue presento una distorsión máxima inelástica de 0.00017, con un punto de desempeño y una ductilidad de 3.5 cm y 24.33 respectivamente, encontrándose dentro de un nivel de desempeño operacional, además de una capacidad de sobrerresistencia de 1.13; mientras que el sistema MDL presenta una distorsión máxima de 0.00012, con un punto de desempeño y una ductilidad de 1.28 cm y 22.58 respectivamente, encontrándose dentro del nivel de desempeño operacional, además de una capacidad de sobrerresistencia de 1.62. De este modo se concluyó que el sistema de Muros de Ductilidad Limitada tendrá una mayor influencia para su comportamiento no lineal.

The research work aimed to determine the influence of structural systems Emmedue and Limited Ductility Walls on the non-linear behavior of the hotel Costa Blanca located in Vichayito, Piura; the type of research was applied, quantitative, explanatory level, with a quasi-experimental design; the population was made up of buildings for hotels whose structural system is based on Emmedue or Limited Ductility Walls in Vichayito, Piura; while the sample was constituted by the Costa Blanca hotel to which it will be analyzed under the systems Emmedue and Limited Ductility Walls. With the help of the Etabs V19 program, the building was modeled for both systems in order to be able to know the static nonlinear behavior of the structure, obtaining the following results: The Emmedue system presented a maximum inelastic distortion of 0.00017, with a performance point and ductility of 3.5 cm and 24.33 respectively, being within an operational performance level, in addition to an overresistance capacity of 1.13; while the Limited Ductility Walls system has a maximum distortion of 0.00012, with a performance point and ductility of 1.28 cm and 22.58 respectively, being within the level of operational performance, in addition to an overresistance capacity of 1.62. Thus, it was concluded that: In this way it was concluded that the system of Walls of Limited Ductility will have a greater influence on the influence for its non-linear behavior.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Privada del Norte. Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Quesada Llanto, Julio; Vega Rivera, Gerson; Vildoso Flores, Alejandro
Register date: 3-Oct-2022



This item is licensed under a Creative Commons License Creative Commons