Title: Diseño estructural del bloque 1 de un colegio en el departamento de Lima
Other Titles: Structural design of block 1 of a school in Lima
Advisor(s): Gálvez Arroyo, Mayra Evelyn
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Issue Date: 20-Jun-2024
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: El presente trabajo se desarrollará con el objetivo de diseñar estructuralmente un pabellón de un centro educativo, que cuenta con 2 niveles en un área de 285m^2, situado en la ciudad de Lima, en el distrito de Ate. Esto se logrará realizando el análisis sísmico para evaluar el comportamiento que esta edificación presentaría ante eventuales sismos o terremotos. La edificación se diseña mediante un sistema dual, que incluirá placas y muros portantes, además de columnas, vigas y losas. Se tendrán en cuenta las normativas de análisis y diseño vigentes, las cuales son la norma E.030 y E.060 respectivamente y como softwares de apoyo se utilizarán Etabs, SAP2000, AutoCad y hojas de cálculo Excel. Se cuenta con limitaciones, para lo cual se realizarán estimaciones teniendo en cuenta el peor de los escenarios posibles a fin de realizar un diseño efectivo y conservador, teniendo en cuenta que se trata de una edificación esencial. Se plasmarán en planos estructurales, los detalles como, dimensiones y cuantía de acero para cada uno de los elementos diseñados de la edificación, así como la ubicación de cada uno de estos.

This work will be developed with the objective of structurally designing a pavilion of an educational center, which has 2 levels in an area of 285m2, located in Lima, in the Ate district. This will be achieved by carrying out seismic analysis to evaluate the behavior that this building would present in the event of earthquakes or earthquakes. The building is designed using a dual system, which will include load-bearing plates and walls, as well as columns, beams, and slabs. The current analysis and design regulations will be considered, which are standard E.030 and E.060 respectively, and Etabs, SAP2000, AutoCad and Excel spreadsheets will be used as support software. There are limitations, for which estimates will be made considering the worst possible scenario to carry out an effective and conservative design, taking into account that it is an essential building. Details such as dimensions and amount of steel for each of the designed elements of the building, as well as the location of each of these, will be reflected in structural plans.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Serrano Lazo, Malena Alessandra; Soto Oblea, Edward Jonathan
Register date: 31-Jul-2024