Look-up in Google Scholar
Full metadata record
Mejia Trejo, Paulo
Condezo Romero, Yino Luis (es_PE)
Rodriguez Zamora, Marco Antonio (es_PE)
2024-01-13T03:27:19Z
2024-01-13T03:27:19Z
2023-11-15
http://hdl.handle.net/10757/671123
El propósito del presente trabajo, consiste en diseñar y estructurar un edificio de 5 pisos con muros de albañilería y estará ubicado en el distrito de Magdalena en la provincia de Lima, el cual será capaz de lograr un desempeño estructural adecuado y óptimo ante eventos sísmicos. La edificación se cimentará sobre un área que tiene forma rectangular y cuenta con una superficie de 115,60 m2 y un área construida de 96,20 m2 por planta. El edificio se plantea utilizando muros portantes de albañilería, losas aligeradas, placas y columnas de concreto armado. La finalidad del proyecto, fue encontrar una distribución adecuada que nos otorgue la suficiente rigidez en las dos direcciones, con el objetivo de controlar el desplazamiento lateral y evitar el momento torsional. La distribución de los elementos de albañilería en la edificación, fue parte vital del trabajo, ya que permitió una buena adaptación a la geometría del plano, así como la colocación de las columnas de concreto que fueron diseñadas uniformente para evitar la reacción torsional ante un sismo. En cuanto a su comportamiento, la simetría es la base de la eficiencia arquitectónica, por ello, la importancia de colocar muros en las dos direcciones y darles continuidad vertical desde la cimentación, la cual aporta mayor rigidez estructural. En cuanto al uso de software y hojas de cálculo, es importante aclarar que son de gran soporte en el análisis y el diseño de las estructuras, sin embargo, se debe tener cuidado al ingresar los datos o pretender sobredimensionarlos, ya que, de esta manera, se obtendrán resultados erróneos, por ello, deben usarse con los criterios adecuados, tomando en cuenta los conocimientos aprendidos.
The purpose of this work is to design and structure a 5-story building with masonry walls and will be located in the district of Madgalena in the province of Lima, which will be capable of achieving adequate and optimal structural performance in the face of seismic events. The building will be founded on an area that has a rectangular shape and has an area of ​​115.60 m2 and a constructed area of ​​96.20 m2 per floor. The building is planned using load-bearing masonry walls, lightened slabs, reinforced concrete plates and columns. The purpose of the project was to find an adequate distribution that gives us sufficient rigidity in both directions, with the aim of controlling lateral displacement and avoiding torsional moment. The distribution of the masonry elements in the building was a vital part of the work, since it allowed a good adaptation to the geometry of the plan, as well as the placement of the concrete columns that were designed uniformly to avoid the torsional reaction in the event of an earthquake. Regarding its behavior, symmetry is the basis of architectural efficiency, therefore, the importance of placing walls in both directions and giving them vertical continuity from the foundation, which provides greater structural rigidity. Regarding the use of software and spreadsheets, it is important to clarify that they are of great support in the analysis and design of structures, however, care must be taken when entering the data or trying to oversize them, since, in this way, erroneous results will be obtained, therefore, they must be used with appropriate criteria, taking into account the knowledge learned.
Trabajo de Suficiencia Profesional (es_PE)
application/pdf (en_US)
application/epub (en_US)
application/msword (en_US)
spa (es_PE)
Universidad Peruana de Ciencias Aplicadas (UPC) (es_PE)
info:eu-repo/semantics/openAccess (es_PE)
http://creativecommons.org/licenses/by-nc-sa/4.0/ (*)
Universidad Peruana de Ciencias Aplicadas (UPC) (es_PE)
Repositorio Académico - UPC (es_PE)
Desplazamiento lateral
Momento torsional
Eficiencia arquitectónica
Continuidad vertical
Rigidez estructural
Lateral displacement
Torsional momento
Architectural efficiency
Vertical continuity
Structural rigidity
Análisis y diseño de una edificación de albañilería de 5 pisos ubicado en el distrito de Magdalena (es_PE)
Analysis and Design of a five-story masonry building located in the Magdalena district
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Peruana de Ciencias Aplicadas (UPC). División de Estudios Profesionales para Ejecutivos (EPE) (es_PE)
Ingeniería Civil (es_PE)
Licenciatura (es_PE)
Ingeniero Civil (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.01.01
https://purl.org/pe-repo/ocde/ford#2.00.00 (es_PE)
https://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
46416316
0000-0001-9829-7735 (es_PE)
73048721
10328770
732016 (es_PE)
Arevalo Vidal, Samir Augusto
Gálvez Arroyo, Mayra Evelyn
https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional (es_PE)
Privada societaria



This item is licensed under a Creative Commons License Creative Commons