Title: Factores de importancia para el diseño de aisladores sísmicos para una edificación multifamiliar de concreto armado con diferentes alturas en Lima, Perú
Other Titles: Important factors for the design of seismic isolators for a multi-family reinforced concrete building with different heights in peru
Advisor(s): Orihuela Dávila, Junior Didi
OCDE field: http://purl.org/pe-repo/ocde/ford#2.00.00; https://purl.org/pe-repo/ocde/ford#2.01.00
Issue Date: 19-Aug-2021
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: En muchos países sufren bastantes movimientos sísmicos, que en algunos casos de severa intensidad, que han ocasionado pérdidas de vidas humanas, económicas. Por ello, se realiza el diseño de edificaciones para soportar sismo de gran intensidad y que el comportamiento de la estructura sea inelástico, para que no pueda colapsar y permita la evacuación de las personas. Ante esta situación, la estructura queda severamente dañada y el costo de reparación es alto. En las últimas décadas, se ha generado sistemas de protecciones sísmicas, lo que engloba un amplio estudio de variedades y tipos de investigaciones. Uno de los temas más estudiados son los sistemas de aisladores sísmicos, ya que separa la superestructura del suelo, es decir que los desplazamientos y aceleraciones de la estructura y del suelo son diferentes. En este estudio se propone el uso del sistema de aisladores sísmicos, con el uso del aislador elastomérico con núcleo de plomo (Lead Rubber Bearing, siglas en ingles LRB), se hace el diseño del aislador de un edificio de concreto armado de diferentes alturas (6, 8 y 10 pisos) con 4 normas de diferentes países (NTP E.031, NCh 2745, ASCE 7-16 y NZS 1170.5). Para poder identificar los factores de mayor importancia en un diseño de aislador. Finalmente, se realiza la comparación de las derivas, desplazamientos y aceleraciones.

In many countries they suffer quite a few seismic movements, which in some cases of severe intensity, that have caused loss of human lives, economic losses. For this reason, buildings are designed to withstand high-intensity earthquakes and the behavior of the structure is inelastic, so that it cannot collapse and allows the evacuation of people. In this situation, the structure is severely damaged and the cost of repair is high. In the last decades, systems of seismic protection have been generated, which includes a wide study of varieties and types of investigations. One of the most studied subjects is the systems of seismic isolators, since it separates the superstructure from the soil, that is to say, the displacements and accelerations of the structure and the soil are different. In this study, the use of the seismic isolator system is proposed, with the use of the elastomeric lead rubber bearing (LRB), the isolator design of a reinforced concrete building of different heights (6, 8 and 10 floors) with 4 standards from different countries (NTP E.031, NCh 2745, ASCE 7-16 and NZS 1170.5). In order to identify the most important factors in an insulator design. Finally, the comparison of drifts, displacements and accelerations is made.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de ingeniería
Grade or title: Ingeniero Civil
Register date: 4-Sep-2021