Aquino, J., Miranda, H. (2021). Propuesta de rehabilitación con “textile reinforced mortar” de un reservorio de agua apoyado de concreto armado con fisuras no estructurales en el distrito de Villa Maria Del Triunfo [Tesis, Universidad Peruana de Ciencias Aplicadas (UPC)]. http://hdl.handle.net/10757/656883
Aquino, J., Miranda, H. Propuesta de rehabilitación con “textile reinforced mortar” de un reservorio de agua apoyado de concreto armado con fisuras no estructurales en el distrito de Villa Maria Del Triunfo [Tesis]. PE: Universidad Peruana de Ciencias Aplicadas (UPC); 2021. http://hdl.handle.net/10757/656883
@misc{renati/396417,
title = "Propuesta de rehabilitación con “textile reinforced mortar” de un reservorio de agua apoyado de concreto armado con fisuras no estructurales en el distrito de Villa Maria Del Triunfo",
author = "Miranda Bellido, Herbert Edwin",
publisher = "Universidad Peruana de Ciencias Aplicadas (UPC)",
year = "2021"
}
This thesis is to demonstrate that it is possible to rehabilitate a supported reinforced concrete water reservoir with the presence of non-structural cracks using Textile Reinforced Mortar (TRM). For the development, one of the thirteen reservoirs that appear in the study for the expansion and improvement of the drinking water and sewerage systems of sectors 311, 313, 330, 310, 312, 314, 300, 307, was chosen as a sample. 319, 324, and 301 Nueva Rinconada, districts of San Juan de Miraflores, Villa María del Triunfo and Villa el Salvador. The selected reservoir is R -6A, which is approximately 30 years old and has a capacity of 750 m3. To propose the rehabilitation of the chosen structure, it was necessary to identify the origin of the failure, so in addition to the structural diagnosis obtained from the technical file of the profile, the structural configuration of the reservoir was obtained with the data taken in the field. In this way, the results found allowed to verify that the design proposed more than 30 years ago complies with the current regulations and it was verified that the failures that the reservoir presents are not structural. Likewise, the calculations allowed the location of the affected area to be known, information that was necessary to prepare the rehabilitation proposal with TRM. The alternative selected for the reservoir wall rehabilitation is the Textile Reinforced Mortar (TRM) system. In this thesis, the tests corresponding to this composite material were carried out and the procedure for rehabilitation is proposed, as well as the quality tests necessary to guarantee the appropriate use of this technology in constant development.
This item is licensed under a Creative Commons License