Look-up in Google Scholar
Title: Análisis numérico del control de infiltración de la fundación de la presa Coltani mediante el uso de pantalla de pilotes secantes
Other Titles: Numerical analysis of the seepage control of the foundation in the Coltani dam through the use of a secant pile wall
Advisor(s): Cárdenas Guillén, Jorge Luis
OCDE field: http://purl.org/pe-repo/ocde/ford#2.00.00; https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 14-Apr-2021
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: En este artículo, se realizó un análisis de infiltración de agua en la presa de tierra Coltani ubicada en el departamento de Tacna, Perú. Primero, se realizó un análisis de infiltración mediante el programa Slide el cual permite evaluar flujos de agua por medio de la hipótesis flujo permanente, de manera bidimensional y con un suelo isotrópico. Luego, se estudió la infiltración del agua subterránea de la presa Coltani tanto en su condición inicial como en su condición con muro pantalla. En esta última, se consideró como referencia el caudal de infiltración máximo permisible para proponer las alternativas en relación a su ubicación. Se consideró un diámetro de 1.5 metros y una profundidad de 30 metros con posibles ubicaciones al inicio, centro y final de la presa. Finalmente, se obtuvieron diversos resultados de caudales de salida en el primer estrato del suelo demostrando el impacto generado por las diversas ubicaciones de los pilotes secantes como muro impermeable. Se obtuvo como principal resultado, la ubicación ideal de los pilotes secantes al final de la presa Coltani con un valor de infiltración del agua subterránea de 0.00276 m3/s en el estrato inicial, verificándose en relación al caudal de infiltración máximo permisible (Qfmp).

In this article, a water seepage analysis was performed in the Coltani earth dam located in the department of Tacna, Peru. First, a seepage analysis was carried out using the Slide program, which allows to evaluate water flows through the permanent flow hypothesis, in a two-dimensional way and with an isotropic soil. Subsequently, the seepage of the underground water from the Coltani dam was studied, both in its initial condition and in its condition as a barrier wall. The maximum allowable seepage flow was considered as a reference to propose the alternatives in relation to its location. A diameter of 1.5 meters and a depth of 30 meters were considered with possible locations at the beginning, center and end of the dam. Finally, various outflow results were obtained in the first soil stratum, demonstrating the impact generated by the various locations of the secant piles as an impermeable wall. The main result was the ideal location of the secant piles at the end of the Coltani dam with a groundwater seepage value of 0.00276 m3/s in the initial stratum, verified in relation to the maximum allowable seepage flow (Qfmp).
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de ingeniería
Grade or title: Bachiller en Ingeniería Civil
Register date: 5-May-2021



This item is licensed under a Creative Commons License Creative Commons