Objetivo: Comparar in vitro la microdureza y rugosidad superficial del cerómero antes y después de su exposición a una bebida energizante. Materiales y métodos: Este estudio fue de tipo experimental in vitro. Se evaluaron 20 discos tipo cilíndricos (6 mm de altura y 4 mm de ancho) del cerómero SR Adoro® divididos en dos grupos para evaluar la microdureza superficial y rugosidad superficial. El desafío erosivo se realizó por 30 minutos/1 vez/ 5 días con la bebida Red Bull®. El análisis estadístico que se utilizó para evaluar la microdureza superficial fue la prueba de Wilcoxon. Sin embargo, para evaluar la rugosidad superficial se utilizó la prueba de T Student. Resultados: Se encontraron diferencias estadísticamente significativas al evaluar la microdureza superficial. Sin embargo, no se encontraron diferencias significativas al evaluar la rugosidad superficial del cerómero. La media y desviación estándar de la microdureza superficial del cerómero SR Adoro® antes del desafío erosivo fue de 55.45 + 6.42 MPa y después del desafío erosivo fue de 38.24 + 6.09 MPa. La diferencia de microdureza superficial inicial y final fue de 17.21+ 0.33 MPa. La media y desviación estándar de la rugosidad del cerómero SR Adoro® antes del desafío erosivo fue de 1.66 + 0.30 y después fue de 1.703 + 0.43 µm. La diferencia de rugosidad inicial y final del cerómero SR Adoro® expuesta a la bebida (Red Bull®) fue de 0.04+ 0.33 µm. Conclusiones: Existen diferencias estadísticamente significativas al evaluar la microdureza superficial. Sin embargo, no se encontraron diferencias estadísticamente significativas al evaluar la rugosidad del cerómero SR Adoro® (p<0.05; p=0.808) al ser expuesta a una bebida energizante Red Bull®. (en_US)
Objective: To compare in vitro the superficial microhardness and roughness of the ceromer before and after being exposed to an energizing drink. Materials and methods: This study was of experimental type in vitro. Twenty cylindrical discs (6 mm high and 4 mm wide) of the SR Adoro® ceromer were divided into two groups to evaluate the surface microhardness and surface roughness. The erosive challenge was performed for 30 minutes / 1 time / 5 days with the Red Bull® drink. The statistical analysis that was used to evaluate the surface microhardness was the Wilcoxon test. However, the Student's T test was used to evaluate the surface roughness. Results: Statistically significant differences were found when evaluating surface microhardness. However, no significant differences were found when evaluating the roughness of the ceromer. The mean and standard deviation of the surface microhardness of the SR Adoro® ceromer before the erosive challenge was 55.45 + 6.42 MPa and after the erosive challenge was 38.24 + 6.09 MPa. The difference of initial and final surface microhardness was 17.21 + 0.33 µm. The mean and standard deviation of the rugosity of the SR Adoro® ceromer before the erosive challenge was 1.66 + 0.30 µm and then was 1.703 + 0.43 µm. The initial and final roughness difference of the SR Adoro® ceromer exposed to the beverage (Red Bull®) was 0.04 + 0.33 µm. Conclusions: There are statistically significant differences when evaluating surface microhardness. However, no statistically significant differences were found when assessing the rugosity of the SR Adoro® ceromer (p<0.05, p = 0.808) when exposed to a Red Bull® energy drink. (en_US)
Tesis (es_PE)
application/pdf (en_US)
application/epub (en_US)
application/msword (en_US)
spa (es_PE)
Universidad Peruana de Ciencias Aplicadas (UPC) (en_US)
info:eu-repo/semantics/openAccess (es_PE)
http://creativecommons.org/licenses/by-nc-sa/4.0/ (*)
Universidad Peruana de Ciencias Aplicadas (UPC) (es_PE)
Repositorio Académico - UPC (es_PE)
Bebidas energéticas (en_US)
Pruebas de dureza (en_US)
Rugosidad (en_US)
Cerómero (en_US)
Energy drinks (en_US)
Hardness tests (en_US)
Roughness (en_US)
Ceromer (en_US)
Comparación in vitro de la microdureza y rugosidad del cerómero antes y después de su exposición a una bebida energizante (en_US)
info:eu-repo/semantics/bachelorThesis (en_US)
Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ciencias de la Salud (es_PE)
Odontología (es_PE)
Licenciatura (es_PE)
Cirujano dentista (es_PE)
PE (es_PE)
http://purl.org/pe-repo/renati/nivel#tituloProfesional (es_PE)
http://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada societaria



This item is licensed under a Creative Commons License Creative Commons