Look-up in Google Scholar
Title: Diseño del servicio de agua potable y unidades básicas de saneamiento en localidades del distrito de Pomahuaca – Jaén – Cajamarca
Advisor(s): Perrigo Sarmiento, Félix Gilberto
Keywords: Fuentes de AguaCaudal
OCDE field: http://purl.org/pe-repo/ocde/ford#2.01.00
Issue Date: 2024
Institution: Universidad Privada Antenor Orrego
Abstract: El presente trabajo de investigación, se desarrolló debido a la problemática que presenta el sistema de agua potable y alcantarillado de la zona de estudio, ya que no cuentan con ambos sistemas haciendo que los pobladores tengan dificultades, debido a que el abastecimiento del agua se da producto del acarreo de diferentes fuentes cercanas (ríos, manantiales, quebradas y/o canales). En cuanto al saneamiento, no se cuenta con un adecuado sistema de evacuación de excretas, la población realiza sus necesidades fisiológicas en pozos ciegos y otros a campo abierto, lo que promueve la proliferación de enfermedades. Se realizó los estudios de campo pertinentes, como la verificación en campo de la cantidad de lotes y el sentido hacia donde desaguarían, se calculó la población proyectada bajo todos los parámetros. Por ello se realizó primero un levantamiento topográfico de todos los sectores identificando cada vivienda para la colocación de su UBS, de igual manera se hizo el estudio de suelo en todos los sectores para verificar el tipo de suelo y la filtración. Así mismo se realizó un estudio de mecánica de suelos conociendo así las características de la textura de suelo y se desarrolló un estudio de la calidad del agua conociendo sus características físicas, químicas y microbiológicas. Finalmente, se verifico que todos los cálculos cumplan con las normas y así lograr un buen diseño óptimo para las personas.

The present research work was developed due to the problems presented by the drinking water and sewage system in the study area, since they do not have both systems, causing the residents to have difficulties, because the water supply is product of transport from different nearby sources (rivers, springs, streams and/or canals). Regarding sanitation, there is no adequate excreta evacuation system, the population carries out its physiological needs in blind wells and others in the open field, which promotes the proliferation of diseases. The pertinent field studies were carried out, such as field verification of the number of lots and the direction in which they would drain, the projected population was calculated under all parameters. For this reason, a topographic survey of all sectors was first carried out. identifying each home for the placement of its UBS, in the same way did the soil study in all sectors to verify the type of soil and the filtration. Likewise, a study of soil mechanics was carried out, thus knowing the characteristics of the soil texture and a study of the quality of the soil was developed water knowing its physical, chemical and microbiological characteristics. Finally, it was verified that all calculations comply with the standards and thus achieve a good optimal design for people
Discipline: Ingenieria Civil
Grade or title grantor: Universidad Privada Antenor Orrego. Facultad de Ingenieria
Grade or title: Ingeniero Civil
Juror: Vega Benites, Jorge Antonio; Vargas López, Segundo Alfredo; Rodríguez Ramos, Mamerto
Register date: 13-Jun-2024