Look-up in Google Scholar
Title: Valor de Gamma Glutamil transpeptidasa comparada con bilirrubina sérica total en el diagnostico de coledocolitiasis
OCDE field: http://purl.org/pe-repo/ocde/ford#3.02.27
Issue Date: 2022
Institution: Universidad Privada Antenor Orrego. Facultad de Medicina Humana
Abstract: Determinar que la gamma glutamil transpeptidasa tiene mayor utilidad que la bilirrubina sérica total en el diagnóstico de colédocolitiasis. Material y métodos: Se realizó un estudio de tipo retrospectivo de pruebas diagnósticas en el que se incluyen a 182 pacientes diagnosticados con colelitiasis, conforme a los criterios de selección se los dividió en un grupo con colédocolitiasis y el otro grupo sin colédocolitiasis, posteriormente se calculó el área bajo la curva. Resultados: La frecuencia de fosfatasa alcalina elevada e hipertransaminasemia en el grupo con colédocolitiasis es estadísticamente significativo a comparación del grupo sin colédocolitiasis, siendo p<0.05. Los valores obtenidos de la GGT en el diagnóstico de la colédocolitiasis fueron los siguientes: sensibilidad (83%), especificidad (79%), valor predictivo positivo (43%), valor predictivo negativo (96%) y la exactitud diagnóstica fue de 84%. Los valores obtenidos de la bilirrubina sérica total en el diagnóstico de la colédocolitiasis fueron los siguientes: sensibilidad (73%), especificidad (69%), valor predictivo positivo (30%), valor predictivo negativo (93%) y la exactitud diagnóstica fue de 74%. Conclusión: l La gamma glutamil transpeptidasa tiene mayor utilidad que la bilirrubina sérica total en el diagnóstico de colédocolitiasis

To determine if gamma glutamyl transpeptidase is more useful than total serum bilirubin in the diagnosis of choledocholithiasis. Material and methods: A retrospective study of diagnostic tests was conducted in which 182 patients diagnosed with cholelithiasis are included, according to the selection criteria they were divided into one group with choledocholithiasis and the other group without choledocholithiasis, subsequently the area under the curve was calculated. Results: The frequency of high alkaline phosphatase and hipertransaminasemia in the group with choledocholithiasis is statistically significant comparison of the group without choledocholithiasis, being p <0.05. The values obtained from the GGT in the diagnosis of choledocholithiasis were the following: sensitivity (83%), specificity (79%), positive predictive value (43%), negative predictive value (96%) and the diagnostic accuracy was 84%. The values obtained from total serum bilirubin in the diagnosis of choledocholithiasis were the following: sensitivity (73%), specificity (69%), positive predictive value (30%), negative predictive value (93%) and diagnostic accuracy was 74%. Gamma glutamyl transpeptidase is more useful than total serum bilirubin in the diagnosis of choledocholithiasis. Conclusion: Gamma glutamyl transpeptidase is more useful than total serum bilirubin in the diagnosis of choledocholithiasis
Discipline: Medicina
Grade or title grantor: Universidad Privada Antenor Orrego. Facultad de Medicina Humana
Grade or title: Medico Cirujano
Juror: Martell Vargas, Alex Berti; Morales Ramos, Eloísa Perpetua; Salazar Briceño, Antonio
Register date: 11-Aug-2022



This item is licensed under a Creative Commons License Creative Commons