Abstract: En la presente investigación se logró determinar el análisis de la vulnerabilidad sísmica mediante el Método de Benedetti – Petrini en viviendas autoconstruidas del sector I en el Centro Poblado El milagro, Trujillo, mediante la aplicación de los 11 parámetros de evaluación; asimismo se logró determinar el análisis sísmico mediante la aplicación del Software Etabs; en donde primeramente se realizó el cálculo de la densidad de muros, posteriormente se realizó el metrado de cargas de cada uno de los muros, verificación de fuerza axial, seguidamente análisis sísmico y finalmente se determinó la figuración de muros; en donde se determinó que mediante el índice de vulnerabilidad mediante el Método de Benedetti – Petrini, resulta con un índice de vulnerabilidad alta; quedando en detalle a continuación: Finalmente, se determinó el Índice de vulnerabilidad, el cual presenta un valor de IV = 42.16%; lo que representa una vulnerabilidad alta. Asimismo, luego de verificar la fuerza axial, se determinó que es conforme, asimismo se comprobó que la edificación cumple con la rigidez lateral; y no presenta agrietamiento de muros

In the present investigation, it was possible to determine the analysis of seismic vulnerability using the Benedetti - Petrini Method in self-built homes in sector I in the Centro Poblado Elmira, Trujillo, through the application of the 11 evaluation parameters; Likewise, the seismic analysis was determined through the application of the Etabs Software; where first the calculation of the density of walls was carried out, then the load measurement of each of the walls was carried out, verification of axial force, then seismic analysis and finally the configuration of walls was determined; where it was determined that through the vulnerability index using the Benedetti – Petrini Method, it results in a high vulnerability index; remaining in detail below: Finally, the vulnerability index was determined, which has a value of IV = 42.16%; which represents a high vulnerability. Likewise, after verifying the axial force, it was determined that it complies, it was also verified that the building complies with the lateral rigidity; and does not present cracking of walls.
Discipline: Ingenieria Civil
Grade or title grantor: Universidad Privada Antenor Orrego. Facultad de Ingenieria
Grade or title: Ingeniero Civil
Juror: Galicia Guarniz, William Conrad.; Cancino Rodas, César Leonidas.; Moran Guerrero, Víctor Manuel
Register date: 9-Aug-2024



This item is licensed under a Creative Commons License Creative Commons