OBJETIVO: Evaluar la utilidad de la electromiografía en el diagnóstico de radiculopatía por hernia discal. MATERIAL Y MÉTODO: Estudio observacional analítico de pruebas diagnósticas. Participaron 231 pacientes con cuadro clínico sugerente o compatible con radiculopatía por hernia discal, elegidos mediante muestreo aleatorio simple, todos ellos atendidos en el Hospital de Alta Complejidad Virgen de la Puerta durante el periodo 2015 – 2018 en quienes se realizó estudio diagnóstico mediante resonancia magnética y electromiografía; la información fue recolectada de los registros en las historias clínicas. Todos ellos cumplieron con los criterios para ingresar al estudio, los intervalos de confianza se estimaron al 95%. RESULTADOS: Se estimó que la electromiografía presenta una sensibilidad de 84,21% (78,08% - 90,34% IC), especificidad de 78,48% (68,79% - 88,18% IC), valor predictivo positivo de 88,28% (82,69% - 93,86%), valor predictivo negativo de 72,09% (62,03% - 82,15%), razón de probabilidad positiva de 3,91, razón de probabilidad negativa de 0,20 y exactitud del 82,25%. CONCLUSIÓN: La electromiografía es útil en el diagnóstico de radiculopatía por hernia discal, con una exactitud diagnóstica de 82,25%. (spa)
OBJECTIVE: To evaluate the utility of electromyography in the diagnosis of radiculopathy due to herniated disc. MATERIAL AND METHOD: Analytical observational study of diagnostic test. Patients with a clinical picture suggestive or compatible with radiculopathy due to herniated disc were studied, who were treated at the Hospital de Alta Complejidad Virgen de la Puerta during the period 2015 - 2018 in whom a diagnostic study was performed using magnetic resonance imaging and electromyography; The information was collected from the records in the clinical history of these patients. A total of 231 study subjects were included who met the criteria for entering the study, chosen by simple random sampling. RESULTS: Electromyography was estimated to have a sensitivity of 84.21% (78.08% - 90.34%), specificity of 78.48% (68.79% - 88.18%), positive predictive value of 88, 28% (82.69% - 93.86%), negative predictive value of 72.09% (62.03% - 82.15%), positive probability ratio of 3.91, negative probability ratio of 0, 20 and accuracy of 82.25% (confidence intervals were estimated at 95%). CONCLUSION: Electromyography is useful in the diagnosis of radiculopathy due to herniated disc, with a diagnostic accuracy of 82.25%. (eng)
Tesis (spa)
application/pdf (eng)
spa (spa)
Universidad Privada Antenor Orrego - UPAO (spa)
T_MED_3329;
info:eu-repo/semantics/openAccess (eng)
https://creativecommons.org/licenses/by/4.0/ (eng)
Universidad Privada Antenor Orrego (spa)
Repositorio institucional - UPAO (spa)
Electromiografía (spa)
Radiculopatía (spa)
Diagnóstico (spa)
Utilidad de la electromiografía en el diagnóstico de la radiculopatía por hernia discal (spa)
info:eu-repo/semantics/bachelorThesis (eng)
Universidad Privada Antenor Orrego. Facultad de Medicina Humana (spa)
Medicina (spa)
Medico Cirujano (spa)
PE (spa)
http://purl.org/pe-repo/ocde/ford#3.01.00 (spa)
http://purl.org/pe-repo/renati/level#tituloProfesional (spa)
17925766
https://orcid.org/0000-0001-9570-8703
72189283
912016
Segura Plasencia, Niler Manuel (spa)
Jara García, Wilmer. (spa)
Torres Vasquez, Percy Alexander (spa)
http://purl.org/pe-repo/renati/type#tesis (spa)
Privada asociativa



This item is licensed under a Creative Commons License Creative Commons