Buscar en Google Scholar
Registro completo de metadatos
Caballero García, Carmen Stefany
Gonzales Soto, Néstor
Rodríguez Lozano, Christopher Peter (*)
2019-02-25T01:57:38Z
2019-02-25T01:57:38Z
2018-12-04
1. Rodríguez Lozano CP. Evaluación de la resistencia a la tracción diametral y microdureza de un cemento experimental (a base de óxido de zinc, cemento portland y arcilla dolomita) como material restaurador provisional en endodoncia [Internet]. [Lima, Perú]: Universidad Peruana de Ciencias Aplicadas (UPC); 2018 [cited 2019 Feb 26]. Available from: https://repositorioacademico.upc.edu.pe/handle/10757/625157 (es_PE)
http://hdl.handle.net/10757/625157
Objetivo: El objetivo del estudio es evaluar la resistencia a la tracción diametral y microdureza del cemento experimental y de materiales de restauración temporal utilizados en endodoncia (Óxido de zinc y Eugenol, Ionómero de vidrio convencional, Clip F® y Coltosol® F). Materiales y métodos: El estudio fue de tipo experimental in vitro. Se confeccionaron 11 muestras para cada cemento provisional, por cada propiedad a evaluar. Posteriormente, las muestras fueron almacenadas a temperatura ambiente por 24 h. Se midió la resistencia a la tracción diametral por compresión a través de la máquina de ensayo universal Instron® y la microdureza a través del Microdurómetro punta Vickers. Los resultados fueron analizados mediante estadística descriptiva univariada y para el análisis bivariado se realizó la prueba de Kruskal Wallis. Resultados: El cemento experimental obtuvo valores mayores de resistencia a la tracción diametral (0.77 MPa + 0.34) en comparación al Coltosol ® F (0.41 MPa + 0.13). Además, obtuvo mayores resultados de microdureza (9,45 HV + 0.66) en comparación al Coltosol ® F (6.50 HV + 0.61) y Óxido de zinc y Eugenol (5,62 HV + 0.61). Sin embargo, presentó menores valores de resistencia a la tracción diametral en comparación del ionómero de vidrio (24.46 + 4.55) y Clip F® (23.06 + 2.91). Asimismo, presento menores valores de microdureza comparado con el Ionómero de vidrio convencional (38.62 + 0.67) y Clip F® (26.03 + 1.07). En ambas propiedades se encontraron diferencias estadísticamente significativas (p<0.05). Conclusiones: El cemento experimental no demostró ser un buen material a comparación del Ionómero de vidrio convencional y el Clip F®. Sin embargo, obtuvo mejores valores que el Óxido de zinc y Eugenol, y Coltosol®; los cuales son empleados comúnmente en el ámbito odontológico a pesar de tener propiedades deficientes. (en_US)
Objective: The objective of this study is to evaluate the diametral tensile strength and microhardness of an experimental cement and temporary restorative materials used in endodontics (Zinc Oxide and Eugenol, conventional glass ionomer, Clip F® and Coltosol® F). Material and methods: The sample of this in vitro study consisted in 11 samples were made from each provisional restorative materials, for each property to be evaluated. The samples were stored at room temperature for 24 h. The diametral tensile strength by compression was measured through the Instron® universal testing machine and the microhardness through the Vickers tip microdurometer. The results were analyzed using univariate descriptive statistics and the Kruskal Wallis test was performed for the bivariate analysis. Results: In this study, the experimental cement obtained higher values of diametral tensile strength (0.77 MPa + 0.34) in comparison of Coltosol® F (0.41 MPa + 0.13). In addition, it obtained higher microhardness results (9.45 HV + 0.66) in comparison of Coltosol ® F (6.50 HV + 0.61) and Zinc Oxide and Eugenol (5.62 HV + 0.61). However, lower diametral strength values were observed compared to glass ionomer (24.46 + 4.55) and Clip F® (23.06 + 2.91). Also, the microhardness values were lower compared to the conventional glass ionomer (38.62 + 0.67) and the Clip F® (26.03 + 1.07). In both properties, statistically significant differences were found (p <0.05). Conclusions: The experimental cement did not prove to be a good material compared to the conventional glass ionomer and the Clip F®. However, it obtained better results than Zinc Oxide and Eugenol, and Coltosol® F; which are commonly used in the dental field despite having poor properties. (en_US)
Tesis (es_PE)
application/pdf (en_US)
application/epub (en_US)
application/msword (en_US)
spa (es_PE)
Universidad Peruana de Ciencias Aplicadas (UPC) (en_US)
info:eu-repo/semantics/openAccess (es_PE)
http://creativecommons.org/licenses/by-nc-sa/3.0/us/ (*)
Universidad Peruana de Ciencias Aplicadas (UPC) (es_PE)
Repositorio Académico - UPC (es_PE)
Pruebas de dureza (en_US)
Cemento dentario (en_US)
Endodoncia (en_US)
Materiales dentales (en_US)
Odontología (en_US)
Evaluación de la resistencia a la tracción diametral y microdureza de un cemento experimental (a base de óxido de zinc, cemento portland y arcilla dolomita) como material restaurador provisional en endodoncia (en_US)
Evaluation of diametral tensile strength and microhardness of an experimental cement (based on zinc oxide, portland cement and dolomite clay) as provisional restorative material in endodontics (en_US)
info:eu-repo/semantics/bachelorThesis (en_US)
Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ciencias de la Salud (es_PE)
Odontología (es_PE)
Licenciatura (es_PE)
Cirujano dentista (es_PE)
PE (es_PE)
http://purl.org/pe-repo/renati/nivel#tituloProfesional (es_PE)
http://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada societaria



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons