La tesis a presentar tiene como objetivo principal realizar el análisis no lineal pushover al hospital de Chiclayo para así poder determinar el desempeño de la edificación, la cual consta de muros estructurales con placas y pórticos de concreto armado frente a un sismo frecuente, severo y máximo. Lo primero a realizar fue la revisión de los planos según el expediente de la edificación, para luego poder realizar el modelado tridimensional en el software Etabs v.21, respetando los planos, propiedades de cada elemento estructural y materiales que se utilizó en la edificación. Asimismo, se debe verificar que la edificación cumpla con las normas técnicas peruanas, entre ellas tenemos a las normas E.020 (Cargas), E.030 (Severo sismorresistente) y E.060 (Concreto Armado). De ello se obtuvo que la edificación no presenta ninguna irregularidad, ni por altura ni por planta. Para determinar la no linealidad de los elementos estructurales de la edificación, se le asignaron rótulas plásticas siguiendo los criterios de aceptación de la norma ASCE/SEI 41-17. Para el análisis pushover se emplearon las metodologías del FEMA 440 y ATC – 40, para evaluar el desempeño de la edificación se utilizó la metodología del espectro de capacidad (ATC – 40), resultando tener un buen desempeño para un sismo frecuente, severo y máximo. También, se evaluó para un sismo máximo considerado según la Norma E.031 (Aislamiento sísmico), obteniendo resultados favorables en su cortante para la edificación. En conclusión, el hospital de Chiclayo mostró un buen desempeño frente a los diferentes sismos aplicados.
The main objective of the thesis to be presented is to carry out the nonlinear pushover analysis of the Chiclayo hospital in order to determine the performance of the building, which consists of structural walls with reinforced concrete plates and frames against a frequent, severe and maximum earthquake. . The first thing to do was review the plans according to the building file, to then be able to carry out the three-dimensional modeling in the Etabs v.21 software, respecting the plans, properties of each structural element and materials that were used in the building. Likewise, it must be verified that the building complies with Peruvian technical standards, among them we have standards E.020 (Loads), E.030 (Severe earthquake-resistant) and E.060 (Reinforced Concrete). From this it was obtained that the building does not present any irregularity, neither in height nor in floor. To determine the nonlinearity of the structural elements of the building, plastic hinges were assigned following the acceptance criteria of the ASCE/SEI 41-17 standard. For the pushover analysis, the FEMA 440 and ATC – 40 methodologies were used, to evaluate the performance of the building, the capacity spectrum methodology (ATC – 40) was used, resulting in good performance for a frequent, severe and maximum earthquake. . Also, it was evaluated for a maximum earthquake considered according to Standard E.031 (Seismic Isolation), obtaining favorable results in its shear for the building. In conclusion, the Chiclayo hospital showed good performance against the different earthquakes applied.
Trabajo de Suficiencia Profesional (es_PE)
application/pdf (en_US)
application/msword (en_US)
application/epub (en_US)
spa (es_PE)
Universidad Peruana de Ciencias Aplicadas (UPC) (es_PE)
info:eu-repo/semantics/openAccess (es_PE)
http://creativecommons.org/licenses/by-nc-sa/4.0/ (*)
Universidad Peruana de Ciencias Aplicadas (UPC) (es_PE)
Repositorio Académico - UPC (es_PE)
Análisis Pushover
Punto de desempeño
Desempeño sísmico
Curva de capacidad
Rótulas plásticas
Pushover analysis
Performance point
Seismic performance
Capacity curve
Plastic hinges
Estudio de desempeño sísmico del hospital de Chiclayo frente a un evento sísmico frecuente, severo y máximo, empleando un análisis estático no lineal Pushover (es_PE)
Study of seismic performance of the Chiclayo hospital against a frequent, severe and maximum seismic event, using a nonlinear static Pushover analysis
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería (es_PE)
Ingeniería Civil (es_PE)
Licenciatura (es_PE)
Ingeniero Civil (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.01.01
https://purl.org/pe-repo/ocde/ford#2.00.00 (es_PE)
https://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
46418416
0009-0007-8996-5130 (es_PE)
72649490
72031531
732016 (es_PE)
Serrano Lazo, Malena Alessandra
Ramirez Guanilo, Cesar Augusto
https://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional (es_PE)
Privada societaria



This item is licensed under a Creative Commons License Creative Commons