Bibliographic citations
This is an automatically generated citacion. Modify it if you see fit
Diaz, R., (2024). Comparación de dos sistemas rotatorios sobre su resistencia a la fatiga cíclica: estudio in vitro [Universidad Católica Santo Toribio de Mogrovejo]. http://hdl.handle.net/20.500.12423/8079
Diaz, R., Comparación de dos sistemas rotatorios sobre su resistencia a la fatiga cíclica: estudio in vitro []. PE: Universidad Católica Santo Toribio de Mogrovejo; 2024. http://hdl.handle.net/20.500.12423/8079
@misc{renati/1107194,
title = "Comparación de dos sistemas rotatorios sobre su resistencia a la fatiga cíclica: estudio in vitro",
author = "Diaz Arango, Roberto Carlos",
publisher = "Universidad Católica Santo Toribio de Mogrovejo",
year = "2024"
}
Full metadata record
Jaime Salloum, Luis Alberto (es_PE)
Diaz Arango, Roberto Carlos
Chiclayo (es_PE)
Diaz Arango, Roberto Carlos
2025-01-07T17:50:29Z
2024
Diaz R. Comparación de dos sistemas rotatorios sobre su resistencia a la fatiga cíclica: estudio in vitro [Tesis de segunda especialidad]. Chiclayo: Universidad Católica Santo Toribio de Mogrovejo; 2024. 51 p. Disponible en: (es_PE)
RTU007744
http://hdl.handle.net/20.500.12423/8079
El presente estudio ha buscado comparar la resistencia a la fatiga cíclica in vitro de dos sistemas rotatorios: Pro flexi file y de One curve en simuladores de conducto radicular de acero inoxidable. Se ha contado con una metodología cuasi experimental, recuperando datos de 40 limas nuevas, 20 limas del sistema One Curve y 20 del Pro Flexi File, considerando el recojo de datos por medio de un dispositivo análogo. Los resultados indicaron que, según la prueba t de Welch con p>0.05, existe una diferencia significativa entre los grupos One curveS y Pro flexiS, sugiriendo que la resistencia a la fatiga in vitro por tiempo de fractura del sistema One curve es significativamente menor que la del sistema Pro flexi. Esto destaca la importancia de considerar las propiedades de resistencia al elegir sistemas rotatorios para procedimientos endodónticos. Se ha concluido que los datos revelan una variabilidad significativa en la resistencia a la fatiga de Pro flexiS, lo que podría tener implicaciones en su rendimiento y durabilidad en comparación con otros sistemas rotatorios. Además, se ha establecido una diferencia estadística entre las dos variables, sugiriendo una menor resistencia a la fatiga in vitro por número de ciclos en el sistema One curve en comparación con el sistema Pro flexi. (es_PE)
The present study has sought to compare the in vitro cyclic fatigue resistance of two rotary systems: Pro flexi file and One curve in stainless steel root canal simulators. A quasi- experimental methodology has been used, recovering data from 40 new files, 20 files from the One Curve system and 20 from the Pro Flexi File, considering data collection through an analog device. The results indicated that, according to Welch's t test with p>0.05, there is a significant difference between the One curveS and Pro flexiS groups, suggesting that the in vitro fatigue resistance by fracture time of the One curve system is significantly lower than that of the Pro flexi. This highlights the importance of considering strength properties when choosing rotary systems for endodontic procedures. It has been concluded that the data reveal significant variability in the fatigue resistance of Pro flexiS, which could have implications for its performance and durability compared to other rotary systems. Furthermore, a statistical difference has been established between the two variables, suggesting a lower in vitro fatigue resistance per number of cycles in the One curve system compared to the Pro flexi system. (es_PE)
application/pdf (es_PE)
spa (es_PE)
Universidad Católica Santo Toribio de Mogrovejo (es_PE)
info:eu-repo/semantics/embargoedAccess (es_PE)
http://creativecommons.org/licenses/by/4.0/ (es_PE)
Fatiga Cíclica, Limas Endodónticas, Endodoncia (es_PE)
Instrumentación del Conducto Radicular, Aleaciones Dentales, Pruebas in vitro (es_PE)
Fractura de Instrumentos, Resistencia a la Fatiga, Odontología Conservadora (es_PE)
Cyclic Fatigue, Endodontic Instruments, Endodontics (es_PE)
Root Canal Preparation, Dental Alloys, In Vitro Techniques (es_PE)
Instrument Fracture, Fatigue Strength, Conservative Dentistry (es_PE)
Comparación de dos sistemas rotatorios sobre su resistencia a la fatiga cíclica: estudio in vitro (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Católica Santo Toribio de Mogrovejo. Facultad de Medicina (es_PE)
Odontología Carielogía y Endodoncia (es_PE)
Segunda Especialidad en Odontología Carielogía y Endodoncia (es_PE)
PE (es_PE)
http://purl.org/pe-repo/ocde/ford#3.02.14 (es_PE)
http://purl.org/pe-repo/renati/nivel#tituloSegundaEspecialidad (es_PE)
45886841
https://orcid.org/0000-0002-7281-6522 (es_PE)
21519591
911079 (es_PE)
Torres Verástegui, Rocío (es_PE)
Morales Guevara, Aurealuz (es_PE)
Jaime Salloum, Luis Alberto (es_PE)
http://purl.org/pe-repo/renati/type#trabajoAcademico (es_PE)
Privada asociativa
This item is licensed under a Creative Commons License