Look-up in Google Scholar
Title: Evaluación del desempeño sísmico aplicando métodos estáticos no lineales en pabellones de uso esencial en la I. E. N° 41026 María Murillo De Bernal
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.00
Issue Date: 25-Jan-2024
Institution: Universidad Científica del Perú
Abstract: Este proyecto de investigación, hace una “Evaluación del desempeño sísmico aplicando métodos estáticos no lineales en pabellones de uso esencial en la I. E. N° 41026 “María Murillo de Bernal””, en el departamento de Arequipa, basándose en la estructuración de elementos estructurales, aplicando la Norma Técnica Peruana E.030 de Diseño Sismorresistente. Es preciso mencionar que dicha norma, aunque se basa en fuerzas y resistencias, “no tiene un método para evaluar el desempeño estructural de una edificación, lo que significa, que no prevé el comportamiento estructural durante un evento sísmico” (Colos & Tunque, 2020). El estudio de enfoque cualitativo, aplicó el método estático no lineal y el método de coeficiente de desplazamiento (para analizar el punto de desempeño), en dos pabellones de la edificación. Los resultados mostraron que estos pabellones 101 A y 101 B, en la dirección “X”, eran operacionales y de ocupación inmediata, y en la dirección “Y”, no cumplían con el requerimiento de desempeño "Performance Based Seismic Engineering of Buildings"de 1995 del comite vision 2000”, concluyendo que, ante un evento sísmico raro, la estructura de estudio, se encontraría dentro del límite del colapso. Por otro lado, la estructura del bloque 101 A, alcanzó una ductilidad de 5.97, es decir de que presentaría una ductilidad media para la dirección de análisis X. Con respecto a la estructura del bloque 101 B, alcanzó una ductilidad de 6.45, es decir de que presentaría una ductilidad alta para la dirección de análisis X y con respecto a la dirección de análisis Y, esta última presentaría una ductilidad frágil, alcanzando un valor estático de 3.54.

This research project, performs an “Evaluation of seismic performance by applying nonlinear static methods in essential pavilions in the I.E. No. 41026 “María Murillo de Bernal””, in the department of Arequipa, based on the structure of structural elements, applishing the Peruvian Technical Standard E.030 of Seismic Resistant Design. It is worth mentioning that this standard, although it is based on forces and resistance, “has no method for evaluating the structural performance of a building, which means that it does not predict structural behavior during a seismic event.” (Colos & Tunque, 2020). The qualitative approach study applied the nonlinear static method and the displacement coefficient method (to analyze the performance point) to two building pavilions. The results showed that these pavilions 101 A and 101 B, in the “X” direction, were operational and of immediate occupation, and in “Y” direction did not meet the performance requirement “Performance Based Seismic Engineering of Buildings” of 1995 of the vision 2000 committee, concluding that in the event of a rare seismic event, the study structure would be within the boundary of collapse. On the other hand, the structure of the block 101 A, achieved a ductility of 5.97, that is to say that it would present an average ductibility for the direction of analysis X. With regard to the structure of block 101 B, it achieved a ductility of 6.45, that is to say that it would present a high ductibility for the analysis direction X and with regard to analysis direction Y, the latter would show a fragile ductility, reaching a static value of 3.54.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Científica del Perú. Facultad de Ciencias e Ingeniería
Grade or title: Ingeniero Civil
Juror: Ocaña Aponte, Juan Jesús; Wong Ramírez, Félix; Saldaña Ferreyra, Keuson
Register date: 9-Mar-2024



This item is licensed under a Creative Commons License Creative Commons