Bibliographic citations
This is an automatically generated citacion. Modify it if you see fit
Aguirre, J., Cruz, J., Del, S. (2022). Design of haptic vibrational feedback control in upper extremity myoelectric prostheses [Universidad Continental]. https://hdl.handle.net/20.500.12394/11780
Aguirre, J., Cruz, J., Del, S. Design of haptic vibrational feedback control in upper extremity myoelectric prostheses []. PE: Universidad Continental; 2022. https://hdl.handle.net/20.500.12394/11780
@misc{renati/913370,
title = "Design of haptic vibrational feedback control in upper extremity myoelectric prostheses",
author = "Del Carpio Ramirez, Sliver Ivan",
publisher = "Universidad Continental",
year = "2022"
}
Title: Design of haptic vibrational feedback control in upper extremity myoelectric prostheses
Authors(s): Aguirre Cangalaya, Juan Diego; Cruz Anchiraico, José Antonio; Del Carpio Ramirez, Sliver Ivan
Advisor(s): Huamanchahua Canchanya, Deyby Maycol
Keywords: Automatización; Mecatrónica; Diseño de máquinas
OCDE field: http://purl.org/pe-repo/ocde/ford#2.03.02
Issue Date: 2022
Institution: Universidad Continental
Abstract: Current prosthesis systems use haptic technology, have a brain-machine interaction that is dependent on visual feedback from the user, also have limitations by the details of the sense of touch both textures, roughness, weights, and contact forces applied. This research shows the development and implementation of haptic technology in a myoelectric prosthesis of the upper extremity, to simulate the sense of touch in the claw of the prosthesis to obtain a better control in the grip force taking as parameter the reaction and efficiency that the device has in different conditions for the patient to have an improvement in the feedback and the grip force of the prosthesis. For the development of the investigation, the VDI2206 methodology was used, simulating each part of the myoelectric prosthesis in different software for an improvement in the process of signal interpretation. Also by diagramming the motor execution process it facilitates the interpretation of the design. The results of the investigation show an alternative model of the conventional ones contributing with improvements in the signals received by the haptic prosthesis and better ergonomics, in addition, the perceived signals showed a better subjection and sensitivity. From the presented design it is desired to replicate to future research since the presented model can be taken as research material.
Link to repository: https://hdl.handle.net/20.500.12394/11780
Discipline: Ingeniería Mecatrónica
Grade or title grantor: Universidad Continental. Facultad de Ingeniería.
Grade or title: Ingeniero Mecatrónico
Register date: 5-Sep-2022
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.