Look-up in Google Scholar
Full metadata record
Vásquez Alfaro, Iván Eugenio
Luna Tejada, Junior Yair
2020-11-26T00:55:34Z
2020-11-26T00:55:34Z
2020-08-15
Luna, J. Y. (2020). Influencia de los tipos de curadores en concretos con plastificante, retardante y acelerante; sobre la compresión y sorptividad, Trujillo 2020 (Tesis de licenciatura). Repositorio de la Universidad Privada del Norte. Recuperado de https://hdl.handle.net/11537/24548 (es_PE)
624 LUNA 2020 (es_PE)
https://hdl.handle.net/11537/24548
Características de durabilidad, resistencia y economía, han puesto al concreto como unos de los materiales de mayor uso a nivel mundial, sin embargo, a pesar de la evidente importancia de este material, los procedimientos de fabricación, colocación y curado en algunos casos no son los adecuados, afectando de manera directa el comportamiento y calidad del concreto. Para evitar la producción de concretos de bajos calidad se requiere un alto grado de control durante el proceso, pasando por el mezclado y el vaciado, hasta la terminación del curado; es por ello que la investigación se centra en evaluar nuevos curadores Curet z, Per Kuret Y Masterkure HD 220 WB, sobre la resistencia a la compresión y sorptividad en concreto que presenta aditivos. La presente tesis se realizó en Trujillo, en la universidad Privada del Norte y en la Universidad Nacional de Trujillo, se determinó la influencia de los curadores en las propiedades mecánicas y físicas del concreto, para la realización de la tesis se utilizó un diseño experimental, el muestreo fue probabilístico con una población de 308 probetas, para el ensayo de resistencia a la compresión 256 probetas de Ø 10 x 20 cm que se dividen en 4 grupos de 64 probetas para concretos sin aditivo, con plastificante, con retardante y acelerante, para sorptividad 48 probetas de Ø 10 x 5cm, la recolección de datos se realizó con la técnica de la observación, el instrumento utilizado fue la técnica de toma de apuntes, para analizar los datos se empleó la inferencia estadística, el problema es que el curado tradicional en obra no satisface las condiciones mínimas que el concreto necesita para desarrollar sus propiedades. En cuanto a los resultados, la mayor resistencia lo obtuvo Masterkure 220 WB en concretos sin aditivos con 348 kg/cm2 y con plastificante 403 kg/cm2; Per kuret para concretos con retardante 375 kg/cm2 y acelerantes con 356 kg/cm2; para sorptividad se obtuvo como resultado que las probetas cilíndricas curadas por inmersión en agua, poseen menor absorción capilar, porque su curado permite generar mayor tiempo de hidratación al concreto, a diferencia de los curadores que al evaporarse el agua del concreto se genera una red de poros que permite una mayor absorción capilar. Se logró determinar la influencia de los curadores sobre la resistencia a la compresión y sorptividad del concreto, encontrándose que para efectos de compresión los curadores si satisfacen los requerimientos, pero para una permeabilidad del concreto se recomienda analizar el uso de impermeabilizantes. (es_PE)
Characteristics of durability, resistance and economy have made concrete one of the most widely used materials in the world. However, in spite of the evident importance of this material, the manufacturing, placement and curing procedures in some cases are not adequate, directly affecting the behavior and quality of the concrete. In order to avoid the production of low quality concrete, a high degree of control is required during the process, from mixing and pouring, to the completion of the curing; that is why the research is focused on evaluating new Curet z, Per Kuret Y Masterkure HD 220 WB, on the compressive strength and sorptivity in concrete presenting additives. The present thesis was carried out in Trujillo, at the Universidad Privada del Norte and the Universidad Nacional de Trujillo. The influence of the curators on the mechanical and physical properties of concrete was determined. For the realization of the thesis an experimental design was used, the sampling was probabilistic with a population of 308 specimens, for the compressive strength test 256 specimens of Ø 10 x 20 cm were used which are divided into 4 groups of 64 specimens for unmixed, plasticized, retarded and accelerated concrete, for the sorptivity 48 test tubes of Ø 10 x 5cm, the data collection was made with the observation technique, the instrument used was the note taking technique, to analyze the data the statistical inference was used, the problem is that the traditional curing in the work does not satisfy the minimum conditions that the concrete. As for the results, the highest resistance was obtained with Masterkure 220 WB in concrete without additives with 348 kg/cm2 and with plasticizer 403 kg/cm2; by kuret for concrete with retardant 375 kg/cm2 and for accelerators with 356 kg/cm2; for the sorptivity it was obtained as a result that the cylindrical test tubes cured by immersion in water, have less capillary absorption, since its curing allows to generate more time of hydration to the concrete, unlike the cures that when the water evaporates from the concrete, a network of pores is generated that allows a greater capillary absorption. It was possible to determine the influence of the curators on the compressive strength and sorptivity of the concrete, finding that for compressive effects the curators do satisfy the requirements, but for a permeability of the concrete it is recommended to analyze the use of waterproofing. (es_PE)
Tesis (es_PE)
application/pdf (es_PE)
application/msword (es_PE)
spa (es_PE)
Universidad Privada del Norte (es_PE)
info:eu-repo/semantics/openAccess (es_PE)
https://creativecommons.org/licenses/by-nc-sa/3.0/us/ (*)
Universidad Privada del Norte (es_PE)
Repositorio Institucional - UPN (es_PE)
Resistencia a la compresión (es_PE)
Concreto (es_PE)
Construcción (es_PE)
Influencia de los tipos de curadores en concretos con plastificante, retardante y acelerante; sobre la compresión y sorptividad, Trujillo 2020 (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Privada del Norte. Facultad de Ingeniería (es_PE)
Ingeniería Civil (es_PE)
Título Profesional (es_PE)
Ingeniero Civil (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.01.01 (es_PE)
Pregrado (es_PE)
https://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
80524374
https://orcid.org/0000-0002-6717-0501 (es_PE)
76637712
732016 (es_PE)
Vásquez Díaz, Alberto Rubén
Rodríguez Beltrán, Eduar José
Sagastegui Vásquez, Germán
https://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada societaria



This item is licensed under a Creative Commons License Creative Commons