Look-up in Google Scholar
Title: Propuesta de peralte de losas postensadas como parte del sistema lateral para edificios altos con núcleo rígido
Advisor(s): Huaco Cárdenas, Guillermo David
Issue Date: 22-Nov-2019
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: Las losas postensadas se están utilizando últimamente con mayor regularidad, no obstante, hay cierto desconocimiento sobre su uso participando dentro del sistema estructural resistente a fuerzas laterales como las producidas por el sismo o el viento. En este trabajo se usan losas postensadas en dos direcciones como sistemas de pisos en edificaciones altas con núcleo rígido, es decir que cuentan con muros estructurales en la zona media del edificio. Dichas losas postensadas fueron modificadas el momento de inercia bruta (Ig) para estudiar el comportamiento sísmico de los edificios altos como también la respuesta de dichas losas. Este estudio se valida con varios modelos computacionales de edificios, en los cuales se propondrá un peralte con el fin de satisfacer las derivas máximas de los edificios altos establecidas por la norma nacional, variando los momentos de inercia de estas losas postensadas. También se implica la modificación de la resistencia a la compresión del concreto (f’c) de las losas y de los elementos verticales, como también los espesores de muros estructurales. El resultado de este estudio es la obtención de peralte de losa postensada respecto a la variación de la capacidad a la comprensión del concreto (f’c) distribuido en el edificio, espesores de muros en núcleo rígido y el porcentaje de momento de inercia agrietado de las losas postensadas. Punzonamiento fue revisado también en las losas postensadas.

Post-tensioned slabs are being used lately with greater regularity, however, there is some ignorance about their use participating within the structural system resistant to lateral forces such as those produced by the earthquake or the wind. In this work post-tensioned slabs are used in two directions as floor systems in high buildings with rigid core, that is to say that they have structural walls in the middle zone of the building. Those post-tensioned slabs were modified the gross moment of inertia (Ig) to study the seismic behavior of the tall buildings as well as the response of those slabs. This study is validated with several computational models of buildings, in which a slab thickness is proposed in order to satisfy the maximum drifts of the tall buildings established by the national standard, varying the moments of inertia of these post-tensioned slabs. It also involves the modification of the resistance to compression of the concrete (f'c) of the slabs and vertical elements, as well as the thicknesses of structural walls. The result of this study is the obtaining of thickness of post-tensioned slab with respect to the variation of the capacity to compression of the concrete (f'c) distributed in the building, thickness of walls in rigid core and the percentage of cracked moment of inertia of the post-tensioned slabs. Punching was also checked on the post-tensioned slabs.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de ingeniería
Grade or title: Ingeniero Civil
Register date: 14-Feb-2020; 14-Feb-2020



This item is licensed under a Creative Commons License Creative Commons